Provide concentration-time curves.
Usage
pk_curve(
t,
model = "1cmt_oral",
params = list(ka = 2.77, CL = 2.5, V = 25),
dose = 600,
ii = 24,
addl = 0,
ss = F
)
Arguments
- t
Observation time in h, specified as a vector.
- model
The model to use. Must be one of "1cmt_bolus", "1cmt_infusion", "1cmt_oral", "2cmt_bolus", "2cmt_infusion", "2cmt_oral", "3cmt_bolus", "3cmt_infusion", "3cmt_oral". The default is "1cmt_oral".
- params
A named list containing parameter values for the selected model type.
- dose
Dose amount.
- ii
Interdose interval (or tau), in hours (default 24).
- addl
Number of additional doses (default 0).
- ss
Assume steady state concentration (default
FALSE
).
Author
Justin Wilkins, justin.wilkins@occams.com